optical tracking system-based surface guided rt alignrt Search Results


90
Vision RT Ltd visual surface based tracking system alignrt
Visual Surface Based Tracking System Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/visual surface based tracking system alignrt/product/Vision RT Ltd
Average 90 stars, based on 1 article reviews
visual surface based tracking system alignrt - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Vision RT Ltd ceiling-mounted alignrt system
Ceiling Mounted Alignrt System, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/ceiling-mounted alignrt system/product/Vision RT Ltd
Average 90 stars, based on 1 article reviews
ceiling-mounted alignrt system - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Vision RT Ltd alignrt® inbore system
Left panel: Mannheim Ethos LINAC and outer 3D cameras from <t>AlignRT;</t> Right panel: Rear view of AlignRT <t>inBore</t> miniature cameras (VisionRT.com)
Alignrt® Inbore System, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/alignrt® inbore system/product/Vision RT Ltd
Average 90 stars, based on 1 article reviews
alignrt® inbore system - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Vision RT Ltd alignrt sgrt system
Left panel: Mannheim Ethos LINAC and outer 3D cameras from <t>AlignRT;</t> Right panel: Rear view of AlignRT <t>inBore</t> miniature cameras (VisionRT.com)
Alignrt Sgrt System, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/alignrt sgrt system/product/Vision RT Ltd
Average 90 stars, based on 1 article reviews
alignrt sgrt system - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Vision RT Ltd alignrt
Open-face mask immobilization system used in this study: a the mask consisted of two shells, b illustration for typical patient immobilization, where the green shade is for anonymization, c typical reference surface in <t>AlignRT,</t> where the white area represents the ROI contour for surface tracking
Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/alignrt/product/Vision RT Ltd
Average 90 stars, based on 1 article reviews
alignrt - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Vision RT Ltd alignrt system safert
Three major commercial OSI systems are used for SGRT applications in radiotherapy clinics. (A) <t>AlignRT</t> Advanced system, (B) Catalyst+ HD system, and (C) IDENTIFY system. The top row shows the cameras (and projector) in the pod and the bottom row shows the 3-pod OSI systems installed in the treatment room. Note that Varian’s IDENTIFY system has a 4th TOF camera pod above the couch. (Images are taken from vendors’ websites with permission, courtesy of these vendors, copyright (2022), and all rights reserved)
Alignrt System Safert, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/alignrt system safert/product/Vision RT Ltd
Average 90 stars, based on 1 article reviews
alignrt system safert - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Elekta active breathing coordinate (abc)
Three major commercial OSI systems are used for SGRT applications in radiotherapy clinics. (A) <t>AlignRT</t> Advanced system, (B) Catalyst+ HD system, and (C) IDENTIFY system. The top row shows the cameras (and projector) in the pod and the bottom row shows the 3-pod OSI systems installed in the treatment room. Note that Varian’s IDENTIFY system has a 4th TOF camera pod above the couch. (Images are taken from vendors’ websites with permission, courtesy of these vendors, copyright (2022), and all rights reserved)
Active Breathing Coordinate (Abc), supplied by Elekta, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/active breathing coordinate (abc)/product/Elekta
Average 90 stars, based on 1 article reviews
active breathing coordinate (abc) - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Vision RT Ltd surface imaging system alignrt
Three major commercial OSI systems are used for SGRT applications in radiotherapy clinics. (A) <t>AlignRT</t> Advanced system, (B) Catalyst+ HD system, and (C) IDENTIFY system. The top row shows the cameras (and projector) in the pod and the bottom row shows the 3-pod OSI systems installed in the treatment room. Note that Varian’s IDENTIFY system has a 4th TOF camera pod above the couch. (Images are taken from vendors’ websites with permission, courtesy of these vendors, copyright (2022), and all rights reserved)
Surface Imaging System Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/surface imaging system alignrt/product/Vision RT Ltd
Average 90 stars, based on 1 article reviews
surface imaging system alignrt - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Vision RT Ltd alignrt 3d surface tracking system
Three major commercial OSI systems are used for SGRT applications in radiotherapy clinics. (A) <t>AlignRT</t> Advanced system, (B) Catalyst+ HD system, and (C) IDENTIFY system. The top row shows the cameras (and projector) in the pod and the bottom row shows the 3-pod OSI systems installed in the treatment room. Note that Varian’s IDENTIFY system has a 4th TOF camera pod above the couch. (Images are taken from vendors’ websites with permission, courtesy of these vendors, copyright (2022), and all rights reserved)
Alignrt 3d Surface Tracking System, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/alignrt 3d surface tracking system/product/Vision RT Ltd
Average 90 stars, based on 1 article reviews
alignrt 3d surface tracking system - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Vision RT Ltd optical surface monitoring system alignrt
Three major commercial OSI systems are used for SGRT applications in radiotherapy clinics. (A) <t>AlignRT</t> Advanced system, (B) Catalyst+ HD system, and (C) IDENTIFY system. The top row shows the cameras (and projector) in the pod and the bottom row shows the 3-pod OSI systems installed in the treatment room. Note that Varian’s IDENTIFY system has a 4th TOF camera pod above the couch. (Images are taken from vendors’ websites with permission, courtesy of these vendors, copyright (2022), and all rights reserved)
Optical Surface Monitoring System Alignrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/optical surface monitoring system alignrt/product/Vision RT Ltd
Average 90 stars, based on 1 article reviews
optical surface monitoring system alignrt - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Vision RT Ltd aligntrt
Three major commercial OSI systems are used for SGRT applications in radiotherapy clinics. (A) <t>AlignRT</t> Advanced system, (B) Catalyst+ HD system, and (C) IDENTIFY system. The top row shows the cameras (and projector) in the pod and the bottom row shows the 3-pod OSI systems installed in the treatment room. Note that Varian’s IDENTIFY system has a 4th TOF camera pod above the couch. (Images are taken from vendors’ websites with permission, courtesy of these vendors, copyright (2022), and all rights reserved)
Aligntrt, supplied by Vision RT Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/aligntrt/product/Vision RT Ltd
Average 90 stars, based on 1 article reviews
aligntrt - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
RaySearch Laboratories raystation (version 6.1.1.2
Three major commercial OSI systems are used for SGRT applications in radiotherapy clinics. (A) <t>AlignRT</t> Advanced system, (B) Catalyst+ HD system, and (C) IDENTIFY system. The top row shows the cameras (and projector) in the pod and the bottom row shows the 3-pod OSI systems installed in the treatment room. Note that Varian’s IDENTIFY system has a 4th TOF camera pod above the couch. (Images are taken from vendors’ websites with permission, courtesy of these vendors, copyright (2022), and all rights reserved)
Raystation (Version 6.1.1.2, supplied by RaySearch Laboratories, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/raystation (version 6.1.1.2/product/RaySearch Laboratories
Average 90 stars, based on 1 article reviews
raystation (version 6.1.1.2 - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

Image Search Results


Left panel: Mannheim Ethos LINAC and outer 3D cameras from AlignRT; Right panel: Rear view of AlignRT inBore miniature cameras (VisionRT.com)

Journal: Radiation Oncology (London, England)

Article Title: Analysis of intra-fractional surface motion during adaptive radiation therapy and relation of internal vs. external position for prostate cancer

doi: 10.1186/s13014-025-02638-3

Figure Lengend Snippet: Left panel: Mannheim Ethos LINAC and outer 3D cameras from AlignRT; Right panel: Rear view of AlignRT inBore miniature cameras (VisionRT.com)

Article Snippet: The AlignRT® inBore system (Vision RT Ltd., London, UK) is a SGRT technology aimed for patient setup and motion monitoring on ring-based LINACs [ ].

Techniques:

Open-face mask immobilization system used in this study: a the mask consisted of two shells, b illustration for typical patient immobilization, where the green shade is for anonymization, c typical reference surface in AlignRT, where the white area represents the ROI contour for surface tracking

Journal: Radiation Oncology (London, England)

Article Title: Initial clinical experience of surface guided stereotactic radiation therapy with open-face mask immobilization for improving setup accuracy: a retrospective study

doi: 10.1186/s13014-022-02077-4

Figure Lengend Snippet: Open-face mask immobilization system used in this study: a the mask consisted of two shells, b illustration for typical patient immobilization, where the green shade is for anonymization, c typical reference surface in AlignRT, where the white area represents the ROI contour for surface tracking

Article Snippet: The SGRT system commissioned at our institution (Beijing Cancer Hospital, China) is the AlignRT (VisionRT Ltd, London, UK) as show in Fig. . A previous phantom-based study by Zhou et al. [ ] evaluated the motion detection accuracy and isocenter congruence of the AlignRT system, finding that the system was able to identify sub-millimeter and sub-degree shifts and that the isocenter deviation with CBCT was negligible.

Techniques:

AlignRT surface imaging system integrated with a VitalBeam linac. The system consisted of two lateral pods and a rear pod. The surface displacement was represented in 6DoF real-time deltas (RTD)

Journal: Radiation Oncology (London, England)

Article Title: Initial clinical experience of surface guided stereotactic radiation therapy with open-face mask immobilization for improving setup accuracy: a retrospective study

doi: 10.1186/s13014-022-02077-4

Figure Lengend Snippet: AlignRT surface imaging system integrated with a VitalBeam linac. The system consisted of two lateral pods and a rear pod. The surface displacement was represented in 6DoF real-time deltas (RTD)

Article Snippet: The SGRT system commissioned at our institution (Beijing Cancer Hospital, China) is the AlignRT (VisionRT Ltd, London, UK) as show in Fig. . A previous phantom-based study by Zhou et al. [ ] evaluated the motion detection accuracy and isocenter congruence of the AlignRT system, finding that the system was able to identify sub-millimeter and sub-degree shifts and that the isocenter deviation with CBCT was negligible.

Techniques: Imaging

Translational displacements of  AlignRT  RTD and CBCT couch shifts

Journal: Radiation Oncology (London, England)

Article Title: Initial clinical experience of surface guided stereotactic radiation therapy with open-face mask immobilization for improving setup accuracy: a retrospective study

doi: 10.1186/s13014-022-02077-4

Figure Lengend Snippet: Translational displacements of AlignRT RTD and CBCT couch shifts

Article Snippet: The SGRT system commissioned at our institution (Beijing Cancer Hospital, China) is the AlignRT (VisionRT Ltd, London, UK) as show in Fig. . A previous phantom-based study by Zhou et al. [ ] evaluated the motion detection accuracy and isocenter congruence of the AlignRT system, finding that the system was able to identify sub-millimeter and sub-degree shifts and that the isocenter deviation with CBCT was negligible.

Techniques:

Histogram of AlignRT RTD and CBCT couch shifts distribution in a VRT, b LNG and c LAT

Journal: Radiation Oncology (London, England)

Article Title: Initial clinical experience of surface guided stereotactic radiation therapy with open-face mask immobilization for improving setup accuracy: a retrospective study

doi: 10.1186/s13014-022-02077-4

Figure Lengend Snippet: Histogram of AlignRT RTD and CBCT couch shifts distribution in a VRT, b LNG and c LAT

Article Snippet: The SGRT system commissioned at our institution (Beijing Cancer Hospital, China) is the AlignRT (VisionRT Ltd, London, UK) as show in Fig. . A previous phantom-based study by Zhou et al. [ ] evaluated the motion detection accuracy and isocenter congruence of the AlignRT system, finding that the system was able to identify sub-millimeter and sub-degree shifts and that the isocenter deviation with CBCT was negligible.

Techniques:

Rotational displacements of  AlignRT  RTD and CBCT couch shifts

Journal: Radiation Oncology (London, England)

Article Title: Initial clinical experience of surface guided stereotactic radiation therapy with open-face mask immobilization for improving setup accuracy: a retrospective study

doi: 10.1186/s13014-022-02077-4

Figure Lengend Snippet: Rotational displacements of AlignRT RTD and CBCT couch shifts

Article Snippet: The SGRT system commissioned at our institution (Beijing Cancer Hospital, China) is the AlignRT (VisionRT Ltd, London, UK) as show in Fig. . A previous phantom-based study by Zhou et al. [ ] evaluated the motion detection accuracy and isocenter congruence of the AlignRT system, finding that the system was able to identify sub-millimeter and sub-degree shifts and that the isocenter deviation with CBCT was negligible.

Techniques:

Histogram of AlignRT RTD and CBCT couch shifts distribution in a YAW, b PITCH and c ROLL

Journal: Radiation Oncology (London, England)

Article Title: Initial clinical experience of surface guided stereotactic radiation therapy with open-face mask immobilization for improving setup accuracy: a retrospective study

doi: 10.1186/s13014-022-02077-4

Figure Lengend Snippet: Histogram of AlignRT RTD and CBCT couch shifts distribution in a YAW, b PITCH and c ROLL

Article Snippet: The SGRT system commissioned at our institution (Beijing Cancer Hospital, China) is the AlignRT (VisionRT Ltd, London, UK) as show in Fig. . A previous phantom-based study by Zhou et al. [ ] evaluated the motion detection accuracy and isocenter congruence of the AlignRT system, finding that the system was able to identify sub-millimeter and sub-degree shifts and that the isocenter deviation with CBCT was negligible.

Techniques:

Three major commercial OSI systems are used for SGRT applications in radiotherapy clinics. (A) AlignRT Advanced system, (B) Catalyst+ HD system, and (C) IDENTIFY system. The top row shows the cameras (and projector) in the pod and the bottom row shows the 3-pod OSI systems installed in the treatment room. Note that Varian’s IDENTIFY system has a 4th TOF camera pod above the couch. (Images are taken from vendors’ websites with permission, courtesy of these vendors, copyright (2022), and all rights reserved)

Journal: Physics in medicine and biology

Article Title: Advances and potentials of optical surface imaging in radiotherapy

doi: 10.1088/1361-6560/ac838f

Figure Lengend Snippet: Three major commercial OSI systems are used for SGRT applications in radiotherapy clinics. (A) AlignRT Advanced system, (B) Catalyst+ HD system, and (C) IDENTIFY system. The top row shows the cameras (and projector) in the pod and the bottom row shows the 3-pod OSI systems installed in the treatment room. Note that Varian’s IDENTIFY system has a 4th TOF camera pod above the couch. (Images are taken from vendors’ websites with permission, courtesy of these vendors, copyright (2022), and all rights reserved)

Article Snippet: For patient identification, the AlignRT system has added another FDA-approved component, called SafeRT (VisionRT), using a facial identification algorithm based on machine learning, similar to the latest biometric authentication systems built into some mobile devices.

Techniques:

Illustration of AlignRT torso surface images of a male (A and C) and a female subject (B and D) acquired using the AlignRT system. The volume of interest is defined between the 2 vertical lines (green), tilted horizontal line (purple), and anterior surface (A and B). Using the full-exhalation torso surface image as the reference, the torso volume changes are calculated for OSI-based spirometry. The 3D surface views are shown in (C and D) with 3 cutting planes: the tiled horizontal plane, and the 2 vertical planes along the edge of the rib cage to separate the thoracic and abdominal motions. The images are taken from the references (Li, et al. 2015b; Li, et al. 2016b) with permission.

Journal: Physics in medicine and biology

Article Title: Advances and potentials of optical surface imaging in radiotherapy

doi: 10.1088/1361-6560/ac838f

Figure Lengend Snippet: Illustration of AlignRT torso surface images of a male (A and C) and a female subject (B and D) acquired using the AlignRT system. The volume of interest is defined between the 2 vertical lines (green), tilted horizontal line (purple), and anterior surface (A and B). Using the full-exhalation torso surface image as the reference, the torso volume changes are calculated for OSI-based spirometry. The 3D surface views are shown in (C and D) with 3 cutting planes: the tiled horizontal plane, and the 2 vertical planes along the edge of the rib cage to separate the thoracic and abdominal motions. The images are taken from the references (Li, et al. 2015b; Li, et al. 2016b) with permission.

Article Snippet: For patient identification, the AlignRT system has added another FDA-approved component, called SafeRT (VisionRT), using a facial identification algorithm based on machine learning, similar to the latest biometric authentication systems built into some mobile devices.

Techniques: